ORION Integrated Alarm & Control System

SYSTEM PURPOSES
  • collection, process handling, transfer, displaying and logging events of the hold-up, intrusion and fire alarm loops states
  • access control and pass point states checking (control of the turnpikes, turnstiles, gates, locks, doors and so on)
  • videowatching and videochecking of secured objects
  • object fire automation control
  • building service systems control
SYSTEM FEATURES
  • module structure that is optimal for both small and very large objects
  • low cost per one loop or one access point
  • protected control panel and detectors exchange protocol
  • microprocessor loops signal analysis to prevent the sabotage
  • opportunity to use the same Proximity card or Touch Memory key for arm/disarm system and access control
  • partition arming/disarming control by several methods:
    • Stand-alone methods:
      • by keyboard
      • by Touch Memory key
      • by Proximity card
      • by combined method (keyboard and plastic card)
    • Centralized methods:
      • by S2000 control console
      • by S2000-K Keyboard, S2000-KS console
      • by computer
  • check and access control over 254 access points (doors, turnpikes, turnstiles, gateways)
  • videowatching , videochecking and registration of the alarm situations
  • automatic fire-extinguish, alerting, smoke removal, air conditioning devices control

SYSTEM SPECIFICATIONS:

Zone number up to 16 000
Partition number up to 10 000
RS-485 interface devices number up to 127
Users number up to 30 000
RS-485 interface line length up to 4 000 m
RS-485 interface line length with one S2000-PI repeater up to 6 000 m

SUBSYSTEMS FUNCTIONS

Alarm subsystem
  • separate checking of alarm and tamper contacts in one loop
  • protection of loops from sabotage by tracing the loop resistance leaps in operation threshold ranges
  • protection from false detector alarms by high loop voltage (24 V DC) and digital filtering of industrial frequency, pulse, electrostatic and other EMI pickups
  • automatic alarm reset of the loop power supplied detectors at arming
  • Orion Software duty voice warning on possible alarm loops sabotage (when loop resistance has been changed by the value) at the arming
  • different arming/disarming methods
  • all system events logging
  • zones, partitions, access points, detectors/control panels, readers, videocameras states displaying on the room graphic diagrams
  • setting permissions on security system arming/disarming and access control by programming access levels for staff and visitors
  • flexible duties and AUP administrators rights differentiation by multilevel password system and opportunity to connect biometric access restriction systems for entree to software
  • the script control macrolanguage support that provides opportunity to specify one or set of commands to panels/consols, to executive devices and to system software. The commands can be called by the system event, by the task schedule or by the operator
  • voice alarm notification, reading and playing user voice messages
  • multilevel alarm processing
  • information cards creation about each system element, staff member or visitor
  • protection of system from unauthorized runs of programme by operator
  • independent alarm contact and detector blocking contact checking in one loop
  • absence of restrictions on zones number in partitions
Fire subsystem

  • double detector operation recognition in one loop
  • protection from false alarms by automatic loop supplied detectors reset
  • plugging threshold, address and address-analogue detectors
  • dust, smoke and temperature value measurements and displaying graphical statistics on the computer monitor
  • statistics gathering for fire-protection improvement and technical support organization
  • displaying the detectors and devices placements, and the most smoked sensors, temperature at the monitored points, daily, monthly, and annual statistics on the room plans
  • script programming for automatic extinguish system control and warning
Automatic extinguish subsystem

  • off-line or centralized fire protection of civil and industrial buildings with one-direction gas, aerosol or powder extinguish
  • Two fire alarm loops, door sensor, and hand-start sensor circuits states checking
  • Start circuits checking on break and short circuits
  • Automatic extinguish systems starting and operation checking
  • Extinguish systems starting time delay
  • Remote extinguish systems starting by command from S2000 control console
  • Manual local extinguish systems starting
  • Automatic extinguish systems starting when two detectors operation in one or two loops occur
  • Turning on sound and light annunciators (sirens, lightings, etc.)
  • Annunciators circuits checking on break and short circuits
  • Technological equipment control (ventilation system valves, etc.)
  • Automatic extinguish systems starting blocking when a protected room doors are opened
  • Manual (from S2000-ASPT control panel) or remote (from S2000 control console) automatic extinguish system starting reset
  • Turning on/off automatic extinguish system start by Touch Memory keys or Proximity cards
  • Use S2000-KPB check-start consoles to increase start circuit number
  • Service and warning messages transmitting to S2000 control console
  • Access restriction to controls at front panel by the electromechanical lock
  • Mechanical lock on S-2000ASPT front cover
  • Tamper switch protection
  • Build-in backup battery
  • Checking primary and backup battery power supplies, disconnecting discharged battery
  • Advanced devices diagnostics with troubles displaying on built-in indicators
Access control subsystem

  • control by Touch Memory and Proximity-card readers or PIN-code console
  • centralized and distributive (local) access keys storage
  • antipassback checking
  • time zones
  • nonvolatile calendar
  • staff search
  • working hours accounting
  • available staff reporting at current time
  • low cost per one access point
Video watching and video checking subsystem

  • unlimited video cameras number connected to computers
  • video output to monitor
  • motion detection
  • 'leaven things' detection
  • detector area planning
  • digital zoom of images
  • recording video to computer's hard disk and playing from it. Search by data, time and camera number
  • sound alarm alerting
  • recording pre- and post alarm situations and record time adjustment
  • possibility for remote user place creation
  • possibility for remote pan and tilt camera control
  • ?live? video. It's comparison at the same screen with image from database activated by access card control
  • integration into ORION security system
  • system reaction to wide spectrum of events: from alarm and access control to remote system arming
Building service system management
  • analogue parameters measurement (temperature, smoke density, humidity, illumination)
  • conditioning, heating, airing, notification, emergence signalizing systems control
  • script programming for building service systems control. The commands can be called by the measurements, by the system events, by the task schedule or by the operator.

SYSTEM COMPONENTS

Software:

  • duty security operator automated user place (Orion software)
  • security service chief automated user place (NSO software)
  • surveillance automated user place (Inspector+ , Goal and Videospider video systems)
  • ARM S2000 workstation software

Hardware:

  • LCD system console S2000
  • LCD system console S2000M
  • LED system console / keypad S2000-KS
  • LCD remote keypad S2000-К
  • LED alarm status panel S2000-BI
  • Intrusion and fire alarm panel Signal-20 
  • Intrusion and fire alarm panel Signal-20P 
  • Intrusion protection and fire alarm panel (address extender) Signal-20P SMD 
  • Intrusion and fire alarm panel / one door controller S2000-4 
  • 2 readers access controller S2000-2 
  • Touch Memory reader Schityvatel-2 
  • Proximity card reader S2000-Proxy 
  • Proximity card reader S2000-Proxy N 
  • Proximity card reader Proxy-2А 
  • Proximity card reader Proxy-3А, Proxy-3АM 
  • Long-range proximity card reader for parkings Proxy-Long 
  • 4 relay outputs module contolled by RS-485 S2000-SP1 
  • Address transmitting subsystem: SPI-2000А 
    • Analogue addressable controller S2000-KDL 
    • Addressable expander module S2000-АR1 
    • Addressable expander module S2000-АR2 
    • 8 zone addressable expander module S2000-АR8
  • Address detectors and executive devices:
    • Addressable intruder passive infra-red detector
      S2000-IK
    • Addressable acoustic glass break detector S2000-ST 
    • Addressable intruder magnet contact detector S2000-SMK 
    • Addressable analogue optical smoke detector DIP-34А 
    • Addressable analogue heat detector with temperature measuring S2000-IP 
    • Addressable fire manual callpoint IPR 513-3А 
    • 2 relay outputs module contolled by polling loop S2000-SP2
  • Extinguish control panel S2000-АSPT 
  • 6 relay outputs module contolled by RS-485 S2000-КPB 
  • Control console S2000-PU 
  • RS-232/RS-485 Interface converter with galvanic isolation PI-GR
  • RS-232/RS-485 converter with galvanic isolation S2000-PI 
  • Speech dialer / communicator S2000-IT 
  • Back-up Power Supply units (12 V DC or 24 V DC) RIP